Submitted by: Pradipta Kumar Pal
Field Service

The ventilation and air circulation fans of underground railway stations, Metro Railway, often need service. They are 6 feet in diameter rotating at an average of 2000 RPM, powered by variable speed brushless DC motor supplied with 600 VDC. The complex drive circuit requires testing and measuring the electrical parameters with the fan running. Of course, one cannot do that inside the wind tunnel without being sucked up and chopped off. Hence, datalogging multimeters are used, but not without drawbacks as the technician cannot get active reading updates while the tests proceed. The innovative new Fluke 233 can be hooked up and hanged with the ToolPak on the stator of the fan. I can foresee myself holding the remote display in hand while the actual meter is doing the job with the fan running. I can vary the speed and get active reading updates, like watching live news from battlefield while couched on a sofa. The Fluke 233 is a multimeter that I can use the most.

 

Other Interesting Stories

Submitted by: danny a h tong
dantah engineering pte ltd

Often times, my buddy does not report for work and I am left alone to carry on my job in checking the faults of air conditioning systems. Very normal, wall mounted Blower units are installed at high levels for optimum air distribution within the room and condensing units are at low level outside the home. During checks, one technician cannot be at the indoor Blower unit or the outdoor Condensing unit at the same time. Neither can he carry too many tools and equipment plus a ladder at one go. There's a limit to time and ability. Fluke 233 Remote Display Multimeter fits in very fine in a situation like this. The Fluke 233 can be positioned first at the outdoor Condensing unit, with the control terminals clamped. Then the technician can check and verify if the indoor Blower unit is able to send any signal to the outdoor Condensing unit during the switching "on and off". There are many air conditioning equipment distributing companies, sole agents and maintenance teams here which operate their technical teams with their few vans but only one technician each per vehicle. This is due to the normal high staffs turn-over and costs of training and maintaining technicians. The Fluke 233 is undoubtedly a minimum requirement for one man show here.

Submitted by: Rashid. N
Indian Railway

Circuit breaker, current transformers, potential transformers are mostly in open yard in a traction substation of Indian railway. the feature of remote display meter can reduce the time, man power, complexity, and mental stress during installation, trouble shooting, and routine maintenance. the feature help us to read some parameters in high voltage side by connecting the probes of multimeter after taking power block and read the parameters by energizing the HT supply. kindly increase the reach/range to suit in high voltage application

Submitted by: RAMANATHAN
NORTHLAB PTE LTD

WE'RE A LABORATORY DOING CALIBRATIONS OF INSTRUMENTS BOTH ONSITE & INHOUSE. SOMETIMES, WE'RE SHORT OF MANPOWER. AS SUCH, ONLY 1 PERSON DOES TWO JOBS AT 1 TIME. FOR EXAMPLE, WE CALIBRATE HIGH VOLTAGE SOURCES LIKE 40KV DC OR HIGH CURRENT WELDING SOURCES ONSITE. SINCE THESE INSTRUMENTS CAN PRODUCE ELECTRICALLY HAZARDOUS VOLTAGE SIGNALS IT IS UNSAFE TO TAKE MEASUREMENTS STANDING CLOSE TO THEM. HENCE, THERE NEEDS TO BE A DISTANCE CLEARANCE & ALSO THE PERSON NEEDS TO BE ISOLATED FROM THE HV AREA BY MEANS OF BARRICADES. IN THIS CASE, THE FLUKE 233 DMM IS THE BEST MEASUREMENT SOLUTION AS ONE CAN TAKE READINGS REMOTELY WITHOUT HAVING TO STAND CLOSE TO THE METER.

Submitted by: Ricardo S. Danan
Siemens Inc.

I am working with medical equipments that are usually emitting x-rays, during troubleshooting I sometimes need to work on the system while emitting x-ray, we have to wear heavy protective clothing to shield ourselves....If we have a fluke 233 on hand we can do the same troubleshooting away from the unit and without the heavy lead clothing.

Submitted by: Tuan Nazir Samath
Mordent Technologies

I am manager technical in this company our main jobs in electronic and telecomunication audio vedio field .This new Fluke 233 Remote Display Multimeter help us to work out side comunication installation sutch as when working top of the towers and control room .

Submitted by: LimKok Keong
PIC Engineering

We could use this for trouble shooting our customer pick and place system (X Y Table) where we need to leave the meter inside the system and still able to read the measurement outside. What we did now is to connect the 2 measuring point with 2 wire from inside the system to the system front were we can control the system & read the measurement at the same time. This is dangerous if the 2 wire is not proper isolated.

Submitted by: Joseph R. Navarroza
CER Connect

We are engaging in to the Electro Mechanical Services, we conduct or have services mostly on the ship (vessel) to measure what they (costumer) need to repair , With this fluke 233, i can now measure the voltage/Ampere readings of the switchboard, electrical panels at the Ship easily.Thanks to the new innovation..

Submitted by: A.Anthoni Selvam
Grundfos Pumps India Pvt. Ltd

Hi. I believe it is the safest and fastest means of measurement, We do use fluke meters, but this feature enable us to take measurements faster and safer way. Put your probes in a live terminal and turn your body to check measurement - you have chance of getting closer or even touch the live parts, This avoids the risk of turning and doing unwanted excersise during measuring, particularly in live measurements. Also it is the fastest way to measure i know that I can avoid stretching my body and turning each and every time, Thanks and regards, Anthoni Selvam

Submitted by: Philip Tan
ABB Pte Ltd

I am working with ABB and I am a service engineer, Our job scope is the provide field site service to Power Plant DCS. As you might aware that DCS are housed in a enclosed cabinet and there are limited and space constraint. Sometimes is rather difficult to place a Full size Fluke meter in an enclosed cabinet but with the Remote Display Multimeter, I guess is easy to handle, whereas the measuring device can be place apart. As a Service engineer we are more concern on the reading hence the Remote Display provide a handy device for us to handle and and i small and light weight to be place in an enclosed cabinet. Sometime we have to climb up to certain height 2m to 2.3m to take analogue readings and with a Full size Fluke meter it makes us difficult to perform such task. But now with the Remote Display Multimeter we are carrying a 2/3 of its size up the ladder to take mearsurement, it guess is the most efficent and handy way of getting the job done. I suggest the it there is magnet attached behind the remote display will be so much better and we can stick it on the cabinet doors and take measurement at any height we went. One more suggestion if the probe can be make more longer will be better.

Submitted by: U Than Htwe
SembCorp Pte Ltd

We would like to measure in MCC. Put the meter in back of MCC (at the cable terminal) and we can operate motor from front of MCC and view the meter reading. Note: Remote Display Clamp meter Please make the product for Remote Display Clamp Meter. That will be more useful. From operation control panel, we can view the current control panel / MCC does not have current meter in panel display.

Submitted by: Aisah Grace Sarip
Lear Corporation - PETC

As a test engineer in an automotive company where time and quality are of essence, efficient tools and gadgets are our best friends. We carry out test measurements of bulky test boxes, large automated test stands and high-powered and delicate modules which require great effort to attain accurate output. With the birth of Fluke 233 remote display multimeter, we can just bring along with us the multimeter display in our desk while remotely controlling our test setup to run several current and voltage tests and closely monitoring the output by simply looking at the multimeter display. Moreover, we don’t have to worry where to place the multimeter in our test stands and test boxes when doing troubleshooting checks since it only covers a little space for the display to be visibly observed by the test engineer. These, in turn, improve the efficiency and quality of our work. The Fluke 233 is definitely an excellent innovation!

Submitted by: Ikramullah Khan
Sui Northern Gas Pipelines Ltd

I am In-charge of maintenance / electrical instrumentation team with major responsibilities to maintain and troubleshoot Centaur 40 & 50 Gas turbine driven compressor packages, Cat & Jenbacher Gas Generating Sets of 640 KW & 1 MW, Perkin Diesel Gensets of 80-500 KW, MCC, Distribution panels, electric motor etc. This Multimeter will be very handy and beneficial for use in our system. Oftentimes during troubleshooting, I sit on table near control panels with schematic drawing in front of me and advise the maintenance staff member to check different electrical / circuit parameters at this, this, … point in control panel and the ask him what the readout on the meter is. This will be very efficient and time saving to use Fluke 233 Remote display multimeter with display module in front of me and reading the drawing simultaneously. Moreover we have already wide range of Fluke instruments because of its reliability and accuracy.

Submitted by: Yan Andris Amral
PT. United Construction

on my field job, the possibilities to use this remote multimeter device is to measure the output voltage and the frequencies of the backup power generator while its terminal test and main control panel separated by distance. i think this device also can be very helpfull for other applications to use in narrow space of measurement

Submitted by: azhar bin mohd zakaria
dongwha mdf malaysia sdn. bhd.

I am an electrician in this company. My job includes taking meter reading. My greatest problem is to get accurate reading since the machine measurement actually fluctuates a lot. With The remote readed F233 Fluke Multimeter I coluld virtually takes the reading the moment machine in act of problem that way i could detect the machine problem while it showing the actually problem without being have to be at the swich panel and could see the actuall machine problem at the field with the meter reading on hand. How convenient for me if I could have the Fluke 233 Multimeter I can help troubleshoot the machines problems and do corrective action on site without being have to be at the swithboard controlling the on-off buttons. This is why i would congratulate Fluke for their innovative solution for people like me in the field. Azhar

Submitted by: Glenn Sta.Romana
MPPCL

I didn't know that there's such a multimeter. If we have a couple of those instruments, our job in instrumentation will be much easier. The measuring module can be installed in our relay room for measuring voltage signals and the display portion can be read at operator's station at Control Room where we actually feed simulation signals at keyboard. There will be no need for someone at the relay room to have a radio feedbacking the readout there! This test instrument model is great!

Submitted by: RAJAN.V
KAIGA GENERATING STATION

IT IS VERY ESSENTIAL IN NUCLEAR POWER STATION TO CHECK THE MOTORIZED VALVE LIMIT SWITCHES OPERATION. BY CONNECTING IT TO THE EQUIPMENT AND THE DMM DISPLAY CAN BE TAKEN TO SAFE AREA TO CHECK ITS OPERATION.BY THIS RADIATION DOSE RECEIVED WILL BE VERY LESS DUE TO OPERATION FROM CONTROL ROOM TAKES TIME FOR COMMUNICATING.

Submitted by: Ismail Nur
Chevron Indonesia

i've to measure the contact swithes at the hazardous area, for the safety i have to running cable from switches to my Multimeter to avoid the possibility of any dangerous situation and not be in the area. Using remote display multimeter will be best way without running cable. :-)

Submitted by: Professor Dr Bharti Dwivedi
Institute of Electrical Engg, Instt of Engg & Tech., Lucknow

We bought the Fluke Single Phase Harmonic Analysers in the Department and those are well in use for lab, final year projects and research work purposes. With the increasing number of students in the lab classes, and with the less number of experiment tables in the lab, it becomesdifficult to demonstrate the experiment by showing readings to the students. I think the Fluke 233 remote display multimeter will be very useful while demonstrating experiments to a group of 5 -6 students at a time. Apart from this I feel that Fluke may equip us with its various field testing instruments to enable us towork as a third party test agency, as ours is a State Government funded Institute. Fluke may help us in proper advertizing in this regard and may realize the investment by sharing the profit in a time bound manner through an MoU to that effect. Bharti Dwivedi Professor, Electrical Engineering Department Institute of Engineering & Technology, Sitapur Road, Lucknow

Submitted by: Phuchong Srisawat
Truecorp PCL

it would be great if i win and get this multimeter, Fluke 233. i can check volts and ampere usage in the Main DB in Data Center of the company that i work. Sometime i don't have the space to locate the meter in or near the main DB Box so i can ask some one to hold the display and read it.

Submitted by: biplab kishore roy
electronics test and development centre

1.During high voltage measurement with 80K40 probe people required to stay near high voltage source which not that safe. But it the display is visible remotely safety in measurement increases. 2.measurement of current with current clamp in hydal power plant.

Submitted by: Nick de Leon
Allegro Microsystems Philippines, Incorporated

I could use the remote display when monitoring voltage, current or resistance in a high altitude place. With this remote display i could monitor it on my desk from a set frequency without going to the ladder just to check the reading from time to time. It will reduce risk of stepping on a high ladder and reduced down time in a way i could simultaneously monitoring it while doing the reports. It will also a big help when measuring on environment that a person maybe an additional interference. I'll just placed the Multimeter on the test spot while me monitoring the reading 30 feet away from it.

Submitted by: Allan Lobo
Neptune Marine Oil&Gas

Its Very much useful when we are working in remote panel on hight, also useful when working in live panel inside, difficult to keep whole meter inside the panel and check the system, because of less space on the panel compartment and compact design, Its good innovation from Fluke to make our job easy and handy to use this meter anywhere.

Submitted by: Edil Lacanilao
BAG Electronics Inc.

As a long time fluke meter user, I find it amazing that I could actually monitor the measurements of our "electronic ballast" subjected for burn-in testing from the testing station up to my office table. It will replace the costly set-up that I made using a bench meter connected at my Personal Computer through our company network and the time required to start-up the software monitoring system. With this new meter, all I need is to connect the probes to the "ballast" detached the remote display place it beside my PC monitor and there it go, my monitoring starts in just a few minutes. This is what I would do if I got a hold on this new meter.

Submitted by: Chua Sainh Lee
Public Utilities Board WSN Dept.

When carrying out maintenance, calibration and operation of electrical valve (actuator). Actuator is located into the chamber, during the operating of valve by remote/tele control to set the valve to certain percentage of opening in ranges to check the accuracy of the actuator setting. Operation of valve may take a few minute for a few range setting, we can read the meter from the top outside the chamber. After a complete operation of valve opening/closing then we can proceed to adjust the setting inside the chamber.

Submitted by: Paulus Adi Nugraha
PT ANDITIRTA INDONUSA

I was wondering if I can somehow get this meter to work in remote areas. My job needs me to reach high rise poles to measure the low level voltage and calibrate it using a Fluke meter. The meter needs to capture data in mV level voltage, and we need at least 2 guys to perform this job. If I can use this remote display meter, I will do this job easier, cause I need to put the probe in the top of the pole, and I can calibrate the signal using my laptop in the ground level. The application was on laptop and its bit risky if we want to bring it in the top of the pole. Using this meter I hope that I will remove the risk crashing my laptop in accident. With this meter I can more precisely trimming the measurement with more confidence. It will reducing the calibration time without sacrificing the quality of trimming. Good job Fluke, you are the most creative vendor who has a creative idea and willingness to get an idea from the fields.